Pressing the Reset Button Causes the Gate to Operate
This issue is most likely caused by a faulty receiver. Locate the LED Indicator button and the Push Button Input LED below the J2 terminal plug on the Ranger control board.
- Press the LED Indicator button and observe the Push Button Input LED. If the LED comes on, the receiver relay is stuck closed and needs to be repaired or replaced.
- If the Push Button Input LED does not come on, contact the factory for further troubleshooting and information.