Pressing the Reset Button Causes the Gate to Operate

This issue is most likely caused by a faulty receiver. Locate the LED Indicator button and the Push Button Input LED below the J2 terminal plug on the Ranger control board.

  1. Press the LED Indicator button and observe the Push Button Input LED. If the LED comes on, the receiver relay is stuck closed and needs to be repaired or replaced.
  2. If the Push Button Input LED does not come on, contact the factory for further troubleshooting and information.