Dual Gate Opens or Closes Correctly then Immediately Reverses Direction
- Confirm which gate is opening or closing correctly before reversing direction.
- Locate the SW1 switches on the Ranger control board. Switches 3 and 4 should both be on for a dual gate setup. Turn off switch 4 to disable one gate.
- Operate the gate and verify that it stops in the correct position. If it does, turn switch 4 back on and turn switch 3 off. Operate the other gate and verify that it also stops in the correct position. One or both gates may need adjustment.
- Once the gate that needs correction is identified, readjust the limits to the correct position.
Installation & Troubleshooting Guide