E11 Error on the Battery Controller

An E11 on your USAutomatic Battery Controller (520001) means the connected battery voltage has dropped below the controller's cutoff threshold (approximately 10.5 volts). When this happens, the controller shuts down to protect the battery and will not operate the gate or accept a charge until the battery is restored.

What to Do

  1. Remove the battery from the system.
  2. Charge the battery externally with a standard 12V battery charger until it reads at least 12.5 volts.
  3. Load test the battery if possible. A battery that drops back below 10.5V right after charging is likely dead and should be replaced.
  4. Reinstall the battery and reconnect it to the controller.
  5. Check the controller screen. It should now show the normal voltage reading without the E11 error.

Common Causes

Cause Prevention
Old or failing battery Replace every 3-5 years or when it won't hold a charge.
Long cloudy spell Clean the solar panel and verify the charging current.
High standby drain Disconnect unnecessary accessories to reduce overnight drain.
Winter/cold weather Cold reduces battery capacity. Consider upgrading solar panel size.

If you have any further questions, please reach out to our representatives. They are happy to help in any way they can!