USAutomatic 050500 LCR Wireless Keypad (Up to 24 unique 2 to 5 Digit Access Codes)
This tamper-resistant, weatherproof, programmable multi-code wireless keypad can be mounted outside your gate and offer convenient access without carrying a transmitter.
Terms to Understand:
- Access Code - The 2 to 5-digit code used to open the gate (24 unique codes are possible). If the access code is less than five digits, it requires the # sign after code is entered. Example: "2 #." If code is 5 digits the # sign is not required.
- Master Password - The 5-digit code used to access programming features. Factory default is "11111". This should be changed for security reasons. NOT USED TO OPEN GATE.
- Relay 1 - The receiver has 2 relays. P1 (relay 1) is pre-wired to the J1 connector.
- Relay 2 - The receiver has 2 relays. P2 (relay 2) is pre-wired to the "Open/Free Exit" on the J1 connector. Keypad Security Code (Dip Switch Code) - This code makes your keypad unique to your installation. Keypad does not have dip switches like the transmitter; instead, it has virtual dip switches which must be programmed.
- PUK Code "Password Unblocking Key." The PUK code is located inside the keypad and is needed when the master password has been lost. Record in space above for future reference. Must be 5 digits long.
- " * " Key - located on the keypad is used to cancel last command entered.
- Red Light Blinks - When blinking, the keypad is sending a signal to the receiver. Valid access code was entered.
- Note: Do not install keypad until "Learning Access Codes in Receiver" has been completed.
Programming Wireless Keypad
- Programming New Master Password:
- Enter the Master Password "11111".
- Enter "8" If correct, 2 short beeps (if 1 long beep is heard, start over with step 1).
- Enter the Master Password (up to 5 digits), if less than 5 digits, "#" is required.
- Enter "8"
- Enter the Master Password again to verify.
- Press "8" If correct, 2 short beeps - New Master Password is set (If 1 long beep is heard, start over with step 1).
Programming Master Password Back to Factory Default: (11111)
- Enter "11111".
- Press "8" (long beep).
- Enter PUK code. (PUK must be 5 digits).
- Press "8".
- Enter PUK code to confirm.
- Press "8" (2 beeps) Master password reset complete.
Programming the Keypad for Operation
- Create Access Code: (Code you use to operate the gate)
- Enter the Master Password "11111".
- Enter "9" If correct, 2 short beeps (if 1 long beep is heard, start over with step 1).
- Enter the new Access Code (up to 5 digits), if less than 5 digits, "#" is required.
- Enter "9"
- Enter the new Access Code again to verify.
- Enter "1" or "2" representing the relay (relay 1 or 2 in the receiver) you want to control.
- If correct, 2 short beeps (if 1 long beep is heard, start over with step 1).
- Now carry keypad to receiver and go to "creating communication with relay 1" below to complete programming.
Learning Access Codes in Receiver:
- Create Communication with Receiver Relay 1: (Security Code/Dip Switches)
- Carry keypad to receiver location for programming.
- Enter the Access Code for relay 1 on the keypad and continue to press the last key entered (red light blinks).
- Press P1 (learn button) on the receiver until LD (green light) comes on and relay clicks.
Create Communication with Receiver Relay 2: (Security Code/Dip Switches)
- Carry keypad to receiver location for programming.
- Enter the Access Code for relay 2 on the keypad and continue to press the last key entered (red light blinks).
- Press P2 (learn button) on the receiver until LD (green light) comes on and relay clicks.
Deleting Single Access Code:
- Enter the Master Password.
- Press the "7" key. If correct, 2 short beeps (if 1 long beep is heard, start over with step 1).
- Enter the Access Code to be deleted.
- Press the "7" key.
- Reenter the Access Code to be deleted.
- Press the "7" key. If correct, 2 short beeps (if 1 long beep is heard, start over with step 1).
Deleting All Access Codes:
- Enter the Master Password.
- Press the "7" key. If correct, 2 short beeps (if 1 long beep is heard, start over with step 1).
- Reenter the Master Password.
- Press the "7" key.
- Reenter the Master Password.
- Press the "7" key. If correct, 2 short beeps (if 1 long beep is heard, start over with step 1).